Moscow, Moscow, Russian Federation
Ivanovo, Ivanovo, Russian Federation
Yaroslavl, Yaroslavl, Russian Federation
Ivanovo, Ivanovo, Russian Federation
To improve the efficiency of using an air heat pump (AHP), it is important to analyze the thermodynamic parameters of the vapor-compression freon loop cycle. To evaluate all thermodynamic processes in the heat recovery system of the air heat pump and to make calculations, experts frequently use heat charts developed by the manufacturers. The authors propose to use tables on saturation line and superheated vapor line of working refrigerant for approximate calculation of vapor-compression freon loop. As a result of calculation of a theoretical vapor -compression cycle, the authors obtained heat energy values taken by the working body during its continuous phase change: boiling, evaporation, condensation, which were determined by the enthalpy state points at the corresponding sections of operation of AHP elements (evaporator, compressor, condenser). Calculations showed that at creating thermal power at the heat pump output, its determining parameter is the phase change of latent heat of vaporization at boiling and condensation of working body in the closed compression cycle system.
vapor-compression cycle, freon loop, enthalpy, air heat pump
1. Galyuzhin S.D., Lobikova N.V., Lobikova O.M., Galyuzhin A.S. Applicability of Using Modern Energy Saving Ventilation Systems for Construction and Reconstruction of Buildings. Journal of Science and Education of North-West Russia. 2018. V. 4. N 4. P. 27-35 (in Russian).
2. Fedosov S.V., Fedoseev V.N., Zaitseva I.A., Voronov V.A. The Hierarchy Analysis Method in Backing Expert Judgments of Criteria for Increasing the Energy Efficiency of Air Heat Pump. Smart composites in construction. 2021. T. 2. N 2. P. 38-47. DOI: 10.52957 / 27821919_2021_2_38 (in Russian).
3. Abiev R.S. Hydrodynamics and Heat Transfer of Circulating Two-Phase Taylor Flow in Microchannel Heat Pipe: Experimental Study and Mathematical Model. Industrial and Engineering Chemistry Research. 2019. V. 59. N 9. P. 3687-3701. DOI: 10.1021 / acs.iecr.9b04834.
4. Fang X., Wu Q., Yuan Y. A general correlation for saturated flow boiling heat transfer in channels of various sizes and flow directions. International Journal of Heat and Mass Transfer. 2017. V. 107. P. 972-981. DOI: 10.1016 / j.ijheatmasstransfer.2016.10.125.
5. Mazurin I.M., Gerasimov R.L., Korolev A.F., Utkin E.F. Ozone-safe freons. The story of a legend and a simple solution. Space and time. 2014. N 3 (17). P. 250-255 (in Russian).
6. Baimachev E.E., Makarov S.S. Thermal Pump Thermodynamic Cycle Modeling to Extend Temperature Range of Air Recuperator Operation. The Bulletin of Irkutsk State Technical University. 2014. N 6(89). P. 101-106 (in Russian).
7. Bagautdinov I.Z., Kuvshinov N.Ye. Heat sources for heat pumps. Innovative science. 2016. N 3. P. 42-44 (in Russian).
8. Makarov S.S. The use of a heat pump in the system for maintaining the microclimate of high-rise buildings. Proceedings of universities. Investments. Construction. Real estate. 2020. V. 10. N 2 (33). P. 250-257. DOI: 10.21285 / 2227-2917-2020-2-250-257 (in Russian).
9. Danilevsky L.N. Forced ventilation systems with heat recovery of exhaust air for residential buildings. Theory and practice. Minsk, 2014. 128 p. (in Russian).
10. Alo M. Problems with Using the Exhaust Air Heat Pump for Renovation of Ventilation Systems in old Apartment Buildings. Danish Journal of Engineering and Applied Sciences. 2015. P. 44-55. DOI: 10.6084 / M9.FIGSHARE.1510922.
11. Dawidowicz B., Cieslinski J. Heat Transfer and Pressure Drop During Flow Boiling of Pure Refrigerants and Refrigerant/Oil Mixtures in Tube With Porous Coating. International Journal of Heat and Mass Transfer. 2012. V. 55. P. 2549–2558. DOI: 10.1016 / j.ijheatmasstransfer.2012.01.005.
12. Fedosov S.V., Fedoseev V.N., Loginova S.A. Heat Transfer Intensification During Condensation of Refrigerant With Straight Pipelines for a Heat Pump Heating System. E3S Web of Conferences. 2021. V. 258. P. 09050. DOI: 10.1051 / e3sconf / 202125809050
13. Kim D.H., Park H.S., Kim M.S. The effect of the refrigerant charge amount on single and cascade heat pump systems. International Journal of Refrigeration. 2014. V. 40. P. 254-268. DOI: 10.1016 / j.ijrefrig.2013.10.002.
14. Zaritsky G.A., Leonov V.P., Likhachev V.I. Analysis and Selection of Working Media for Gas Circuit of Heat Pump. Engineering Journal: Science and Innovation. 2013. N 1(13). P. 146-148 (in Russian).
15. Harsem T.T., Grindheim J., Borresen B.A. Efficient Interaction Between Energy Demand Surplus Heat, Cooling and Thermal Storage. Procedia Engineering. 2016. N 146. P. 210-217. DOI:https://doi.org/10.1016/j.proeng.2016.06.375.
16. Ovsyannik A.V. Modeling of Heat Exchange Processes During Boiling of Liquids. Gomel: GGTU im. P.O. Sukhogo, 2012. 284 p. (in Russian).
17. Koshelev S.V., Slastikhin Yu.N., Eideyus A.I. Comparative calculations of the heat transfer coefficient during refrigerant boiling in tubes. Vestnik Mezhdunarodnoi akademii kholoda. 2020. N 2. P. 65-72. DOI: 10.17586 / 1606 4313 2020 19 2-65-72 (in Russian).